ML-1000s Series
Convection Cooled
Air Transport Rack
Electronic Equipment Enclosure
 
  • System environmental protection designed to meet MIL-E-5400T Class 1A (Airborne)1 ATR

  • 1 ATR per ARINC 404A / MIL-STD-91403

  • 7.625" tall x 10.125" wide x 12.625" deep

  • EMI protection design to meet MIL-STD-461

  • 115VAC 400Hz input and 28 VDC
    Outputs:

    +5V

    20 Amps

    +12V

    1.6 Amps

    -12V

    1.6 Amps

    +3.3V

    8.0 Amps

    -5.2V

    3.0 Amps

    +28V

    2.0 Amps

  • High-reliability and quiet fan cooling module provides 275 LFM minimum per slot

  • -10° to +55° C Operational

  • Side load 6 slot high-speed jumperless 6U VME64 or CompactPCI backplane -160 mm

  • Brazed Aluminum Construction per MIL-B-7883 for Strength & Light Weight: 26 lbs

  • Vibration: 15 Hz - 2000 Hz/ MIL-STD-810E, Method 514.4, Procedure 1

  • Shock: 30G’s/ MIL-STD-810E, Method 516.4, Procedure 1


Macrolink, Inc. 1500 North Kellogg Drive Anaheim, California 92807-1902
Phone 714.777.8800 Fax 714.777.8807

Macrolink and the Macrolink logo are registered trademarks of Macrolink, Inc. Prices and specifications are subject to change without notice. Copyright 2000-2007, Macrolink, Inc. All rights reserved.