Macrolink's Manx series is a family of premiere quality rugged chassis
designed to meet extreme environmental demands and weight restrictions.
The Manx members of this family set a new standard for lightweight,
high-power VME/cPCI chassis
A precise blend of machined,
formed and extruded members impart an exceptional degree of structural
integrity, while eliminating excess material and significantly reducing
the number of mechanical fasteners for increased reliability and ease of
access to Field Replaceable Units (FRUs).
Access to system boards,
backplane, and rear transition modules is via hinged covers. All
internal and external surfaces are chromate conversion coated with a
powder-coated exterior finish providing maximum protection against
corrosion. All materials and finishes meet fungus and salt atmosphere
resistance per MIL-STD-810E.
The Manx’s card cage
assembly accepts up to ten 6U VME or cPCI boards into a monolithic
backplane. There is ample area on the rear of the chassis assembly to
accommodate the densest of I/O configurations.
An oversized filtered air
intake combined with high-efficiency/high-pressure fans, insures
generous airflow through the card cage. A sophisticated thermal
management design extends the Manx’s operating capability to
environments from -20°C to +55°C ambient.
Complete EMI/RFI
integrity is maintained via conductive interior surfaces, braided
gaskets on all moveable panels and front doors, conductive gaskets on
all mating joints and honeycomb-shielded vent screens front & rear. All
faying surfaces are clear of finish to maintain optimal conductivity.
Macrolink's Manx series
is the ideal chassis to meet the most stringent demands of airborne,
field fixed, naval surface and ground mobile deployments at an
affordable price and the rapid delivery of a COTS enclosure.
|
Specifications
|
|
Construction
& Finish
|
-
Brazed 6061/T6 aluminum per MIL-B-7883, Type V, Grade A
-
All internal/external surfaces chromate conversion coated per
MIL-C-5541 Grade A Class 3
-
External finish is semi-gloss Black, color #27038, in
accordance with TT-E-529, FED-STD 595 & MIL-F-14072
-
Other colors and/or finishes available
|
|
Card
Cage Assembly
|
-
10-Slot 6U VME64 or 10-Slot 6U cPCI backplane (bridged)
-
Auto-Bus Grant
-
Macrolink designed low-impedance backplane
-
Vibration dampened card guides
-
Optional conformal coating (Acrylic or Parylene)
-
Custom, application specific backplanes available
|
|
Switches
& Indicators
|
-
Main Power
switch/circuit breaker
-
Over Temperature
LED – Red
-
Power Good
LED – Green
-
Fan Fail
LED - Red
-
System Reset
switch
-
Elapsed Time Indicator (ETI) reading to 9999 hours
-
¼ x 20 ground stud w/blind nut
|
|
Power
Supply
|
-
1.3KW DC output
-
80% efficiency
over voltage & temperature range
-
Input voltage
range – 108 to 118VAC
-
Over Voltage
Protection
-
Serviceable DC
Modules
-
Qualified to
MIL-STD-704E
|
|
External
Power Connector
|
-
110 – 220 VAC 3-Phase WYE; 47 - 400 Hz
|
|
DC Outputs |
-
+5VDC @ 120A
-
+3.3VDC @ 100A
-
+12VDC @ 15A
-
-12VDC @ 15A
-
Remote sensing on all outputs
|
|
Chassis
I/O
|
-
Removable Rear I/O panel
-
5.75”H x 14.00”W (80.5 Sq. In.) / 146mmH x 356mmW
-
Available blank & finished or pre-punched, finished &
silkscreened
-
I/O panels available with connectors, or connectors & internal
cabling installed
-
Front Mounted USB Interface
|
|
System Monitor Module
|
-
Intelligent, processor driven, system monitoring
-
Monitors temperature, power & fans
-
Real-time system status available via RS-232 or Ethernet
|
|
EMI/RFI
Integrity
|
-
All faying surfaces clear of finish
-
Braided gasket on all removable surfaces
-
Conductive gasket on all mating joints
-
Honeycomb EMI vent screens front & rear
-
EMI/EMC shielding meets JASA standards
|
|
Dimensions
|
-
19” Rack mountable Unit
-
9.5”H x 19.00”W x 18.5”D (241mm H x 483mm W x 470mm D
|
|
Weight
|
-
66 Lbs (24.6Kg) Fully Loaded
|
|
Cooling
|
|
|
Ambient
Temperature
|
-
-25ºC (-13ºF) to +55ºC (+131ºF) Operating
-
-40ºC (-40ºF) to +71º (+160ºF) Non-Operating
|
|
Altitude |
-
0’ to 30,000’ / 0 to 9,140M Operational
-
-1,000’ to 70,000’ / -303.2M to 21,336M Non-Operational
|
|
Humidity
|
-
0 to 95% (Non-Condensing)
|
|
Reliability
(MIL-HDBK-217E)
|
-
MTBF: > 70,000 for fans @ 25°C
-
MTTR: < 30 Minutes
|
|
Environmental
Qualifications
per
MIL-STD-810E
|
|
Shock; Operational |
18 impacts @10Gs for 11ms duration |
|
Shock; Crash Safety |
12 impacts @ 20Gs for 11 ms duration |
|
Vibration; Operating |
5 to 500 Hz |
|
Fungus |
MIL-STD-810E |
|
High/Low Temperature |
Per Methods 501.4 & 502.4 |
|
Altitude |
Per Method 500.4; Procedure III & IV |
|
Humidity |
Per Method 507.4 |
|
EMI/RFI
Qualifications*
per
MIL-STD-461E |
|
Conducted Emissions |
CE101, CE107 |
|
Conducted Susceptibility |
CS101, CS102, CS106 |
|
Radiated Susceptibility |
RS101, RS102, RS103 |
|
Filter Insertion Loss |
Per MIL-STD 220A |
|
ESD |
Per MIL-STD-1686A (Class 3) |
|
|
Part Number |
|
|